HOMEPRODUCTS RAILWAY CABLES

 

Pigtail Rail Connection Cables to SE260L

 

Application:

These connection cables are designed for use in signalling equipment rooms.

Standards:

SE260

UNE 21123

Construction:

Pigtail Rail Connection Cables to SE260L

Conductors

Stranded plain copper conductors to IEC 60228 class 2 or 5.

Insulation

FRPVC.

Outer sheath

FRPVC.

Optional

Limited fi re hazard pigtail rail connection cables: Stranded tinned copper conductors, LSZH composite insulation.

Electrical Characteristics at 20℃:

Nominal Conductor Cross Section mm² 0.6
Maximum DC Conductor Resistance Ω/km 1.15/1.16*
Voltage Rating KV 0.6/1.0

*For LSZH cable

Mechanical and Thermal Properties:

Minimum Bending Radius: 7.5×OD

Temperature Range:-25℃ to +85℃ (during operation);

                                -10℃ to +70℃ (during installation)

Dimensions And Weight:

Cable Code No. of cores& Nominal Conductor Cross
Sectional Area
No.×mm²
No. & Nominal Diameter of
Strands
No/mm
Nominal Insulation
Thickness
mm
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
RF260-VV-K-0.6/1KV-1G16 1×16 19/1.04 0.7 1.4 10.3 249
RF260-RZ1-K-0.6/1KV-1G16 1×16 19/1.04 0.7 1.4 10.3 255

K is changed to U if the stranding class is changed from class 5 to class 2